quartus/thhor_crs.asm.rpt:Warning (18236): Number of processors has not been specified which may cause overloading on shared machines. Set the global assignment NUM_PARALLEL_PROCESSORS in your QSF to an appropriate value for best performance.
quartus/thhor_crs.asm.rpt:Info: Quartus Prime Assembler was successful. 0 errors, 1 warning
quartus/thhor_crs.fit.rpt:Warning (18236): Number of processors has not been specified which may cause overloading on shared machines. Set the global assignment NUM_PARALLEL_PROCESSORS in your QSF to an appropriate value for best performance.
quartus/thhor_crs.fit.rpt:Warning (18550): Found RAM instances implemented as ROM because the write logic is disabled. One instance is listed below as an example.
quartus/thhor_crs.fit.rpt:Warning (292013): Feature LogicLock is only available with a valid subscription license. You can purchase a software subscription to gain full access to this feature.
quartus/thhor_crs.fit.rpt:Warning (15714): Some pins have incomplete I/O assignments. Refer to the I/O Assignment Warnings report for details
quartus/thhor_crs.fit.rpt:Warning (176674): Following 4 pins are differential I/O pins but do not have their complement pins. Hence, the Fitter automatically created the complement pins.
quartus/thhor_crs.fit.rpt: Warning (176118): Pin "S_OUT" is a differential I/O pin but does not have its complement pin. Hence, fitter automatically created the complement pin "S_OUT(n)"
quartus/thhor_crs.fit.rpt: Warning (176118): Pin "D_OUT" is a differential I/O pin but does not have its complement pin. Hence, fitter automatically created the complement pin "D_OUT(n)"
quartus/thhor_crs.fit.rpt: Warning (176118): Pin "S_IN" is a differential I/O pin but does not have its complement pin. Hence, fitter automatically created the complement pin "S_IN(n)"
quartus/thhor_crs.fit.rpt: Warning (176118): Pin "D_IN" is a differential I/O pin but does not have its complement pin. Hence, fitter automatically created the complement pin "D_IN(n)"
quartus/thhor_crs.fit.rpt:Critical Warning (169085): No exact pin location assignment(s) for 1 pins of 56 total pins. For the list of pins please refer to the I/O Assignment Warnings table in the fitter report.
quartus/thhor_crs.fit.rpt:Warning (176250): Ignoring invalid fast I/O register assignments. See the Ignored Assignments panel in the Fitter Compilation Report for more information.
quartus/thhor_crs.fit.rpt:Warning (171167): Found invalid Fitter assignments. See the Ignored Assignments panel in the Fitter Compilation Report for more information.
quartus/thhor_crs.fit.rpt:Warning (169177): 15 pins must meet Intel FPGA requirements for 3.3-, 3.0-, and 2.5-V interfaces. For more information, refer to AN 447: Interfacing Cyclone 10 LP Devices with 3.3/3.0/2.5-V LVTTL/LVCMOS I/O Systems.
quartus/thhor_crs.fit.rpt:Warning (169203): PCI-clamp diode is not supported in this mode. The following 1 pins must meet the Intel FPGA requirements for 3.3V, 3.0V, and 2.5V interfaces if they are connected to devices other than the supported configuration devices. In these cases, Intel recommends termination method as specified in the Application Note 447.
quartus/thhor_crs.fit.rpt:Warning (169064): Following 27 pins have no output enable or a GND or VCC output enable - later changes to this connectivity may change fitting results
quartus/thhor_crs.fit.rpt:Info: Quartus Prime Fitter was successful. 0 errors, 15 warnings
quartus/thhor_crs.map.rpt:; ctick ; Output ; Warning ; Declared by entity but not connected by instance. Logic that only feeds a dangling port will be removed. ;
quartus/thhor_crs.map.rpt:; fifo_e ; Output ; Warning ; Declared by entity but not connected by instance. Logic that only feeds a dangling port will be removed. ;
quartus/thhor_crs.map.rpt:; fifo ; Output ; Warning ; Declared by entity but not connected by instance. Logic that only feeds a dangling port will be removed. ;
quartus/thhor_crs.map.rpt:; afull ; Input ; Warning ; Declared by entity but not connected by instance. If a default value exists, it will be used. Otherwise, the port will be connected to GND. ;
quartus/thhor_crs.map.rpt:; fifo_nonblock ; Input ; Warning ; Declared by entity but not connected by instance. If a default value exists, it will be used. Otherwise, the port will be connected to GND. ;
quartus/thhor_crs.map.rpt:; rbo ; Output ; Warning ; Declared by entity but not connected by instance. Logic that only feeds a dangling port will be removed. ;
quartus/thhor_crs.map.rpt:; ff_full ; Output ; Warning ; Declared by entity but not connected by instance. Logic that only feeds a dangling port will be removed. ;
quartus/thhor_crs.map.rpt:; ff_half ; Output ; Warning ; Declared by entity but not connected by instance. Logic that only feeds a dangling port will be removed. ;
quartus/thhor_crs.map.rpt:; ff_empty ; Output ; Warning ; Declared by entity but not connected by instance. Logic that only feeds a dangling port will be removed. ;
quartus/thhor_crs.map.rpt:; ff_packet ; Output ; Warning ; Declared by entity but not connected by instance. Logic that only feeds a dangling port will be removed. ;
quartus/thhor_crs.map.rpt:; trigger ; Output ; Warning ; Declared by entity but not connected by instance. Logic that only feeds a dangling port will be removed. ;
quartus/thhor_crs.map.rpt:; RXn ; Output ; Warning ; Declared by entity but not connected by instance. Logic that only feeds a dangling port will be removed. ;
quartus/thhor_crs.map.rpt:; fempty ; Output ; Warning ; Declared by entity but not connected by instance. Logic that only feeds a dangling port will be removed. ;
quartus/thhor_crs.map.rpt:; fifo_empty ; Output ; Warning ; Declared by entity but not connected by instance. Logic that only feeds a dangling port will be removed. ;
quartus/thhor_crs.map.rpt:; attn ; Output ; Warning ; Declared by entity but not connected by instance. Logic that only feeds a dangling port will be removed. ;
quartus/thhor_crs.map.rpt:Warning (18236): Number of processors has not been specified which may cause overloading on shared machines. Set the global assignment NUM_PARALLEL_PROCESSORS in your QSF to an appropriate value for best performance.
quartus/thhor_crs.sta.rpt:Warning (18236): Number of processors has not been specified which may cause overloading on shared machines. Set the global assignment NUM_PARALLEL_PROCESSORS in your QSF to an appropriate value for best performance.
quartus/thhor_crs.sta.rpt:Info: Quartus Prime Timing Analyzer was successful. 0 errors, 1 warning